Welding PPE product catalog for B2B sourcingWuxi Yincheng Science & Technology Co., Ltd.
Yincheng company logoWELDING
PROTECTION

PAPR components | Model YC-PR01

Papr Blower Unit: YC-PR01

A PAPR blower unit with listed airflow settings and specific hood references; pictured combinations are not package lists.

papr blower unit model YC-PR01 is presented for distributor and industrial sourcing review. Use the product image and available specifications to define the request, then ask for a current quotation and written confirmation of the supplied configuration.

PAPR sourcing requires a clear distinction between a blower, a hood or helmet and a pictured combination. This page identifies YC-PR01 using the available product information. A combination image is not treated as a package list. The inquiry should name every component that must be included and ask for current documentation for the intended market and work environment.

Quote the blower unit and hood as separate line items

YC-PR01 is the blower-unit record. It lists airflow settings of 220, 180 and 150 liters per minute, one-hour charging time, buzzer alarm and a host weight of 1280 g including the battery and air filter. The listed adapting hoods are YC-H01, YC-H02 and YC-H02W. The page does not make every welding helmet a verified package.

Ask the quotation to identify the blower, battery, filter, belt, hose and selected hood or helmet separately. Also request current filtration documentation and operating instructions for the intended workplace and destination. Do not use a combination photograph as the bill of materials, and do not extend the product to spraying or other industries without a task-specific assessment.

Build the PAPR order as a component checklist

Start with the YC-PR01 blower and select one of the listed hoods: YC-H01, YC-H02 or YC-H02W. Add the battery, charger, belt, hose and air filter as individually confirmed lines. The offer should state which airflow setting and alarm behavior apply, how the 1280 g host weight is measured and what is supplied for replacement filtration. This checklist is more useful than a combination photograph because it can be checked at quotation, packing and receiving stages.

Compare, assess and request

The wider papr components catalog helps buyers compare model identities within the same family. Similar names, dimensions or photographs do not establish interchangeability. Review the related product or family record before selecting a configuration.

Product identification is separate from workplace selection. OSHA publishes welding eye and face protection requirements and shade-selection guidance. Read the welding helmet shade guide and the underlying OSHA welding requirements. These safety references do not certify a catalog model.

Prepare the RFQ

Name YC-PR01, the planned process, desired controls or viewing area, quantity, destination and document requirements. Confirm minimum order, lead time, package contents, spare components and any helmet or filter pairing. If you are replacing a part, include the current model and measured dimensions. Then send a model-specific request so sales can respond against a defined scope.

Available specifications

The information below follows the available product-page text. Ask sales to confirm each required field for the current quotation.

  1. 01Filtration Efficiency                               99.97%
  2. 02Filter Class                                           TH2 PR SL
  3. 03Air Flow                                                220/180/150(L/min)
  4. 04Charging Time                                      1h
  5. 05Rechargeable Time                              >500 times
  6. 06Alarm Mode                                          Buzzer Sound
  7. 07Working Humidity                                 <90%
  8. 08Storage Humidity
  9. 09<85%
  10. 10Host Weight (including battery, air filter)       1280 g
  11. 11Adapting Hood:
  12. 12YC-H01
  13. 13,
  14. 14YC-H02,YC-H02W
  15. 15,

Questions for YC-PR01

Is the pictured configuration the standard package?

No package is inferred from a photograph. Ask sales to list the included model, controls, headgear, filter, lenses, PAPR components and accessories for the quotation.

Does this model fit another brand or helmet?

Provide the target model and dimensions for written compatibility confirmation. Similar appearance or dimensions do not prove fit.

Are the required documents current?

Request the current document set for the quoted model, configuration and destination. An older product-page label is not a substitute for document review.

Related papr components

Continue within the same family.

Compare the exact model details and request written compatibility confirmation where needed.

YC-H01 product image
YC-H01 | PAPR components

YC-H01 PAPR product

Review the product image and available model information.

Review model details
YC-H02 product image
YC-H02 | PAPR components

YC-H02 PAPR product

Review the product image and available model information.

Review model details
YC-H02W product image
YC-H02W | PAPR components

YC-H02W PAPR product

Review the product image and available model information.

Review model details

Model-specific inquiry

Ask about YC-PR01.

Include the work process, quantity, destination and every component that must be confirmed.

Your details are used only to handle this inquiry. See our privacy policy.